Light-Modulated Humidity Sensing in Spiropyran Functionalized MoS₂ Transistors, Adrián Tamayo, Wojciech Danowski, Bin Han, Yeonsu Jeong, Paolo Samorì, Small 2026, 22, 2404633, https://doi.org/10.1002/smll.202404633
This dataset contains the experimental source files and numerical data supporting the data-containing panels of Figures 1–3 in the above-mentioned publication. A numerical transcription of the published results in Table 1 is also included.
The dataset contains:
- UV–Vis absorption spectra of EGO-SP, EGO-MC, C₁₃-SP and C₁₃-MC films deposited on quartz substrates (Fig. 1b).
- Native AFM scans of pristine MoS₂, EGO-SP/MoS₂ and EGO-MC/MoS₂ surfaces (Fig. 1c).
- Transfer characteristics of MoS₂/BCB/SiOₓ transistors before and after EGO-SP deposition, and following successive UV irradiation and thermal annealing treatments (Fig. 2a).
- Relative drain-current changes during reversible switching between EGO-SP and EGO-MC through UV irradiation and thermal annealing (Fig. 2b).
- Transfer characteristics of MoS₂/BCB/SiOₓ transistors before and after C₁₃-SP deposition, and following successive UV irradiation and thermal annealing treatments (Fig. 2c).
- Relative drain-current changes during reversible switching between C₁₃-SP and C₁₃-MC through UV irradiation and thermal annealing (Fig. 2d).
- Transfer characteristics of pristine MoS₂/BCB/SiOₓ transistors measured at different relative humidity levels (Fig. 3a).
- Transfer characteristics of EGO-SP/MoS₂/BCB/SiOₓ transistors measured at different relative humidity levels (Fig. 3b).
- Transfer characteristics of EGO-MC/MoS₂/BCB/SiOₓ transistors measured at different relative humidity levels (Fig. 3c).
- Signed relative-current response slopes and corresponding positive humidity sensitivities for ten transistor structures (Fig. 3e).
- Published threshold voltages, charge-carrier mobilities, photo-modulation efficiencies and thermal-recovery efficiencies, transcribed from Table 1 with the reported uncertainties.
The dataset is provided in a flat structure, with all files located in a single folder. Each data filename identifies the figure and panel, or table, to which it corresponds.
Original text exports and native AFM measurement files are retained without changes to their contents. Numerical CSV tables with descriptive column headers and units are additionally supplied for the quantitative plots. The original acquisition order of the electrical measurements is preserved, including forward and reverse voltage sweeps.
The accompanying readme.txt describes the experimental context, file organization, units, data preparation and differences between source-file labels and the publication. The file_index.csv records the original source paths, file descriptions and SHA-256 checksums.
File Types and Formats:
.csv – numerical data tables corresponding to quantitative figure panels, a transcription of the published parameters in Table 1, and the file index.
.txt – original numerical text exports and the dataset README.
.spm – native Bruker AFM measurement files containing scan data, acquisition metadata and multiple measurement channels.
CSV files are encoded in UTF-8 with a byte-order mark and use a semicolon (';') as the field separator and a comma as the decimal separator.